| Alternative NSN: 5925-01-387-6563 |
| Item Name: Circuit Breaker |
| FSG: 59 Electrical and Electronic Equipment Components |
| Federal Supply Class (FSC): 5925 Circuit Breakers |
| NIIN: 013876563 |
| NCB Code: USA (01) |
| Manufacturers: Siemens Energy And Automation Inc |
Browse NSN parts of NSN 5925-01-387-6563 and get lowest price for your requested parts in 15 minutes. Just ordered part of NSN 5925-01-387-6563 like HED43B030 described as Circuit Breaker from industry leading manufactures such as Siemens Energy And Automation Inc. We are proud to offer an inventory of over 2 billion ready-to-ship parts, 24/7 availability, and key locations in the U.S./abroad. These attributes allow us to meet all aircraft on ground (AOG) requirements with ease.
| Part No | Manufacturer | Item Name | QTY | RFQ |
|---|---|---|---|---|
| HED43B030 | Siemens Energy And Automation Inc | circuit breaker | Avl | RFQ |
| MRC | Criteria | Characteristic |
|---|---|---|
| CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES AC ALL LOCATIONS |
| AKPX | Pole Quantity | 3 |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 42000.0 AC ALL LOCATIONS |
| FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
| CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
| CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| CPRQ | Reset Method | MANUAL |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
| CPRW | Actuator Function | TRIP-RESET |
| CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
| ADAT | Body Width | 3.000 INCHES NOMINAL |
| CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| AJWX | Mounting Surface To Terminal End Distance | 4.000 INCHES NOMINAL |
| ADTV | Case Material | PLASTIC |
| ADAQ | Body Length | 6.343 INCHES NOMINAL |
| TTQY | Terminal Type And Quantity | 6 COMPRESSION |
| AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 480.0 AC ALL LOCATIONS |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 138.0 ALL LOCATIONS |
| CPRX | Actuator Position Designation | AT POLE TWO |
| MRC | Decoded Requirement | Clear Text Reply |
|
5905-00-001-2971 (5905000012971) |
5905-00-001-3031 (5905000013031) |
5905-00-001-3050 (5905000013050) |
|
5905-00-001-3085 (5905000013085) |
5905-00-001-3197 (5905000013197) |
5905-00-001-3806 (5905000013806) |
|
5905-00-001-3819 (5905000013819) |
5905-00-001-3821 (5905000013821) |
5905-00-001-3822 (5905000013822) |
|
5905-00-001-3824 (5905000013824) |
5905-00-001-3825 (5905000013825) |
5905-00-001-3827 (5905000013827) |