| Alternative NSN: 6110-01-527-4668 |
| Item Name: Controller Motor |
| FSG: 61 Electric Wire and Power and Distribution Equipment |
| Federal Supply Class (FSC): 6110 Electrical Control Equipment |
| NIIN: 015274668 |
| NCB Code: USA (01) |
| Manufacturers: California Marine Supply Inc, Drs Power And Control Technologies |
Browse NSN parts of NSN 6110-01-527-4668 and get lowest price for your requested parts in 15 minutes. Just ordered part of NSN 6110-01-527-4668 like 6962CMS1063, 6962CMS1063 described as Controller Motor from industry leading manufactures such as Drs Power And Control Technologies, California Marine Supply Inc. We are proud to offer an inventory of over 2 billion ready-to-ship parts, 24/7 availability, and key locations in the U.S./abroad. These attributes allow us to meet all aircraft on ground (AOG) requirements with ease.
| Part No | Manufacturer | Item Name | QTY | RFQ |
|---|---|---|---|---|
| 6962CMS1063 | Drs Power And Control Technologies | controller motor | Avl | RFQ |
| 6962CMS1063 | California Marine Supply Inc | controller motor | Avl | RFQ |
| MRC | Criteria | Characteristic |
|---|---|---|
| AGAV | END ITEM IDENTIFICATION | AER 28/00, LHD 4 BOXER;FAN COIL UNIT FOR AMMO MAG POWER SYSTEM MODIFICATIONS |
| AJXE | SIZE DESIGNATOR | 1 |
| ANDG | FUSE CURRENT RATING IN AMPS | 10.0 AND 17.0 |
| ANRH | AMP SIZE RATING | 27.0 |
| AKVY | (NON-CORE DATA) ACCESSORY CONTROLLING AGENCY | NAVICP-MECH |
| ANDE | ACTUATOR VOLTAGE | 450.0 AC |
| ANCN | OPERATING VOLTAGE CHARACTERISTIC | FULL OR REDUCED |
| AGUE | FUSE ACCOMMODATION QUANTITY | 13 |
| ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | GENERAL PURPOSE-NEMA TYPE 1 |
| FREQ | FREQUENCY IN HERTZ | 60.0 |
| ANCY | HORSEPOWER RATING | 0.500 |
| ANDX | AMBIENT TEMP | 50.0 DEG CELSIUS |
| FAAZ | PHASE | THREE |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | CONTROLLER, MAGNETIC,SIZE 1, LVR,450VAC 3PH 60HZ |
| ACYN | AC VOLTAGE RATING | 450.0 VOLTS NOMINAL |
| ANPZ | INCLOSURE FEATURE | DRIPPROOF AND EXPLOSION PROOF AND MOISTURE PROOF AND SPRAY TIGHT |
| ANDW | LOAD PROTECTION TYPE | OVERLOAD AND UNDERVOLTAGE RELEASE AND SHORT CIRCUIT AND UNDERVOLTAGE |
| ANQC | NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
| AKVZ | (NON-CORE DATA) ACCESSORY IDENTIFYING NUMBER | -321-7598776 REV A DRAWING NO. |
| FEAT | SPECIAL FEATURES | 13 CONTROLLERS REQUIRED FOR FULL OPERATION OF ALL FAN COIL SYSTEMS;LOW VOLTAGE RELEASE |
| ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
| ANCP | VOLTAGE REDUCTION METHOD | AUTOTRANSFORMER |
| AKPS | DUTY CYCLE | CONTINUOUS AND VARIABLE |
| AFLW | ACTUATION METHOD | MAGNETIC |
| CBBL | FEATURES PROVIDED | ACCESSORY LOCATION INTERNAL AND CIRCUIT PROTECTION FUSE |
| ANCQ | FULL VOLTAGE RESTORING METHOD | CURRENT LIMIT ACCELERATION |
| AQZF | CONTROL TYPE | LOCAL OR REMOTE |
|
6105-00-003-0244 (6105000030244) |
6105-00-003-1852 (6105000031852) |
6105-00-003-2069 (6105000032069) |
|
6105-00-003-3316 (6105000033316) |
6105-00-003-3316 (6105000033316) |
6105-00-003-5258 (6105000035258) |
|
6105-00-003-5314 (6105000035314) |
6105-00-003-6141 (6105000036141) |
6105-00-003-9716 (6105000039716) |
|
6105-00-004-1276 (6105000041276) |
6105-00-004-4496 (6105000044496) |
6105-00-004-6940 (6105000046940) |